Radiation Monitoring

HYDROTRACK RADIATION MONITORING

Background Radiation TIPU SERVICES

online
One continuous dashboard · selected monitor: F3C13DE8
Station statusDEGRADED
Equipment assurance and radiation state are evaluated separately so an instrument fault is not mistaken for a low radiation reading.
Assurance72/100
Self-testWARN
Data completeness33.8 %
6,667 estimated missing · raw
CalibrationDOSE ESTIMATE ONLY
StationConnectionCurrent CPMBackgroundAbove backgroundSigmaState
TIPU SERVICES NP Radiation WAITING 110.0 115.7 -4.9 % -0.48 σ BACKGROUND
Background Radiation TIPU SERVICES ONLINE 19.0 19.8 -4.1 % -0.18 σ BACKGROUND
Current radiation19.0 CPM
Background19.8 CPM
Significance-0.18 σ
Detection stateBACKGROUND
Dose rate0.108 µSv/h
5-minute CPM20.2 CPM
Wi-Fi-28 dBm
Last activity12 minutes ago
Detector GOOD Noise LOW Dose estimate Link online HV NOT_FITTED Uploads 6.3%

Dose and measurement assurance

Professional context derived from the detector’s reported values and counting statistics.

Dose today0.0580 µSvDetector-reported accumulated dose for today.
Session dose0.0580 µSvDetector-reported accumulation for the current session.
Integrated dose — displayed range6.9599 µSvWebsite trapezoidal integration; long communications gaps are excluded.
Annualised estimate0.949 mSv/yProjection from the detector; not a personal dosimetry measurement.
Counting uncertainty±5.7 %Approximate 1σ Poisson uncertainty for the latest interval (√N ≈ 17.5 counts).
Short-term trendFalling -5.9 %Current CPM relative to the 5-minute rolling CPM.
Time ≥2σ in range17.0 minTotal duration of statistically elevated events detected in the selected range.
Uplink reliability6.25 %1 successful / 15 failed
Device uptime31mESP uptime reported with the latest measurement.
Data completeness33.8 %Coverage from the first to last available point in this selected range; chart downsampling is excluded.
Approx. 3σ detection level33.2 CPMPoisson approximation around the current background; the graph’s learned 3σ band remains the primary indicator.
Calibration uncertaintyNot specifiedReported certificate uncertainty when configured on HRV9.5+.

Statistical overview

Summary for the selected graph time range.

Samples1135
Average CPM22.6
Minimum CPM5.0
Maximum CPM195.0
Std deviation23.49
Upload gaps10
Excess CPM-0.8
Above background-4.1 %
Corrected CPM19.0
Background sourceFirmware learned
Background protectionLearning normally

Radiation graphs

Main count-rate graph first, followed by supporting diagnostics in a compact two-column grid.

Count rate, background and thresholds

Unit: CPM — counts per minute. CPM is the detector pulse rate normalised to one minute. This graph shows raw CPM, the 5-minute rolling rate, dead-time-corrected CPM, the resolved background reference, dynamic +1σ/+2σ/+3σ background bands, and the configured warning and alarm thresholds.

Vertical dotted markers: detected radiation-event peaks. Yellow marks an event around 2–3σ above background, orange marks 3–5σ, and pink/red marks 5σ or higher. These are event markers, not extra threshold lines.

Counts per second

Unit: CPS — counts per second. The number of accepted detector pulses in each second. This gives the fastest view of changing radiation activity and can reveal brief spikes.

Counts per upload

Unit: counts (detector pulses). The non-overlapping number of detector pulses accumulated during each upload/reporting interval. This is an interval total rather than a rate.

Cumulative detector counts

Unit: counts (detector pulses). The long-running detector pulse total. It normally rises continuously; device restarts or counter resets can appear as resets or discontinuities.

Significance above background

Unit: σ (sigma) — standard deviations, dimensionless. This shows how far the measured count rate is from the learned background in statistical terms. The 2σ and 3σ lines provide reference levels for increasingly unusual departures from normal background.

CPM distribution histogram

X-axis: CPM; Y-axis: number of samples. The histogram groups recorded CPM readings into ranges and shows how often each range occurred. A tight distribution usually indicates a stable background; widening or extra peaks can help identify changing conditions or noise.

Dose-rate trend

Unit: µSv/h — microsieverts per hour. This is the estimated or calibrated ionising-radiation dose rate derived from detector counts. Its accuracy depends on the detector, energy response, geometry and the CPM-to-dose calibration used.

Environment and cabinet

Live environmental history from the same freshest sensor stream used by Live Data. Temperature, humidity and pressure are merged even when firmware sends them separately from Geiger measurements.

Temperature18.4 °C127.6 h old
Humidity49.6 %127.6 h old
Pressure1,007.2 hPa127.6 h old

Detector instrument-health trends

Engineering measurements from compatible HRV9.4+ monitors. These diagnose the instrument itself rather than environmental radiation.

Detector pulse width

Unit: µs. Stable pulse width helps distinguish genuine module output from wiring noise, missing return edges or malformed pulses.

Radiation events

HydroTrack marks statistically elevated periods so the start, peak and end of an event are easy to identify.

Events in range104
Strongest event3.94 σ
Event threshold2.00 σ
SeverityStartPeakEndDurationPeak CPMPeak σ
Above background 2026-09-12 17:40:42 2026-09-12 17:40:42 2026-09-12 17:40:42 0.0 min 27.0 2.11 σ
Above background 2026-09-11 17:21:29 2026-09-11 17:21:29 2026-09-11 17:21:29 0.0 min 30.0 2.51 σ
Above background 2026-09-11 12:58:29 2026-09-11 12:58:29 2026-09-11 12:58:29 0.0 min 29.0 2.09 σ
Above background 2026-09-11 12:53:30 2026-09-11 12:53:30 2026-09-11 12:53:30 0.0 min 28.0 2.14 σ
Above background 2026-09-11 12:46:28 2026-09-11 12:46:28 2026-09-11 12:46:28 0.0 min 30.0 2.02 σ
Above background 2026-09-09 21:17:45 2026-09-09 21:17:45 2026-09-09 21:17:45 0.0 min 28.0 2.17 σ
Above background 2026-09-09 20:58:45 2026-09-09 20:58:45 2026-09-09 20:58:45 0.0 min 27.0 2.10 σ
Above background 2026-09-09 20:52:45 2026-09-09 20:52:45 2026-09-09 20:52:45 0.0 min 28.0 2.34 σ
Above background 2026-09-09 16:36:49 2026-09-09 16:36:49 2026-09-09 16:36:49 0.0 min 31.0 2.65 σ
Above background 2026-09-09 15:01:47 2026-09-09 15:01:47 2026-09-09 15:01:47 0.0 min 28.0 2.38 σ
Above background 2026-09-08 16:33:24 2026-09-08 16:33:24 2026-09-08 16:33:24 0.0 min 32.0 2.66 σ
Above background 2026-09-08 13:11:13 2026-09-08 13:11:13 2026-09-08 13:11:13 0.0 min 168.0 2.42 σ
Above background 2026-09-08 13:02:13 2026-09-08 13:02:13 2026-09-08 13:02:13 0.0 min 164.0 2.15 σ
Above background 2026-09-08 12:42:15 2026-09-08 12:42:15 2026-09-08 12:42:15 0.0 min 164.0 2.19 σ
Above background 2026-09-08 11:56:13 2026-09-08 11:56:13 2026-09-08 11:56:13 0.0 min 166.0 2.50 σ
Above background 2026-09-08 11:17:12 2026-09-08 11:17:12 2026-09-08 11:17:12 0.0 min 164.0 2.54 σ
Above background 2026-09-08 09:16:36 2026-09-08 09:16:36 2026-09-08 09:16:36 0.0 min 173.0 2.85 σ
Above background 2026-09-08 08:53:32 2026-09-08 08:53:32 2026-09-08 08:53:32 0.0 min 165.0 2.04 σ
Above background 2026-09-08 08:15:12 2026-09-08 08:16:12 2026-09-08 08:16:12 1.0 min 166.0 2.43 σ
Above background 2026-09-08 07:38:31 2026-09-08 07:38:31 2026-09-08 07:38:31 0.0 min 172.0 2.91 σ

Instrument, environment and data quality

Latest detector condition and measurement configuration. Sensitive network and hardware identifiers are intentionally not exposed on the public page.

Detector healthGOOD
Detector noiseLOW
Critical threshold1,000 CPM
Calibration statusDose estimate
Wi-Fi signal-28 dBm
Supply voltageNot reported
Cabinet / tamperOPEN / TAMPER
Tube high voltageNot fitted
HV statusNOT_FITTED
Average pulse width173.1 µs
Invalid pulse widths7.43 %
Dead-time loss0.005 %
Rejected pulses54
Pulse signalVALID_PULSES
Measurement assurancePARTIAL_NO_HV_MONITOR
Station self-testWARN
Input powerNot fitted
Power statusNOT_FITTED
Audit continuity#100
Samples displayed1,135
Instrument record and calibration details
Station IDF3C13DE8
Monitor typeGeiger radiation monitor
FirmwareHRV9.5.28-ENV-SENSOR-READ-RECOVERY-FIX
Detector serialNot configured
Configured efficiency100.0 %
Configured CPM range0 – 100,000 CPM
Calibration dateNot configured
Calibration dueNot configured
Calibration laboratoryNot configured
Uptime31m
Upload counters1 success / 15 failed
Background sourceFirmware learned
HV supervisionNot fitted / disabled
Expected tube HV350 – 550 V
Last pulse width188.0 µs
Dead-time rejected10
Measurement validityVALID
Station assurance72/100 · DEGRADED
Self-test summaryenvironment;environment-quality;
Audit chain hash25425DCB