Radiation Monitoring

HYDROTRACK RADIATION MONITORING

TIPU SERVICES NP Radiation

offline
One continuous dashboard · selected monitor: CD76B144
Station statusDEGRADED
Equipment assurance and radiation state are evaluated separately so an instrument fault is not mistaken for a low radiation reading.
Assurance82/100
Self-testPASS
Data completeness
Insufficient range
CalibrationDOSE ESTIMATE ONLY
StationConnectionCurrent CPMBackgroundAbove backgroundSigmaState
TIPU SERVICES NP Radiation OFFLINE 110.0 115.7 -4.9 % -0.48 σ BACKGROUND
Background Radiation TIPU SERVICES ONLINE 29.0 18.3 +58.3 % 2.49 σ ABOVE BACKGROUND
Current radiation
Background
Significance
Detection stateNO DATA
Dose rate0.627 µSv/h
5-minute CPM118.2 CPM
Wi-Fi-88 dBm
Last activity2 hours ago
Detector GOOD Noise LOW Dose estimate Link offline HV NOT_FITTED Uploads 28.9%

Dose and measurement assurance

Professional context derived from the detector’s reported values and counting statistics.

Dose today2.7946 µSvDetector-reported accumulated dose for today.
Session dose35.5280 µSvDetector-reported accumulation for the current session.
Integrated dose — displayed rangeWebsite trapezoidal integration; long communications gaps are excluded.
Annualised estimate5.496 mSv/yProjection from the detector; not a personal dosimetry measurement.
Counting uncertainty±9.5 %Approximate 1σ Poisson uncertainty for the latest interval (√N ≈ 10.5 counts).
Short-term trendCurrent CPM relative to the 5-minute rolling CPM.
Time ≥2σ in range0.0 minTotal duration of statistically elevated events detected in the selected range.
Uplink reliability28.85 %936 successful / 2,308 failed
Device uptime4d 2hESP uptime reported with the latest measurement.
Data completenessCoverage from the first to last available point in this selected range; chart downsampling is excluded.
Approx. 3σ detection levelPoisson approximation around the current background; the graph’s learned 3σ band remains the primary indicator.
Calibration uncertaintyNot specifiedReported certificate uncertainty when configured on HRV9.5+.

Statistical overview

Summary for the selected graph time range.

Samples0
Average CPM
Minimum CPM
Maximum CPM
Std deviation
Upload gaps0
Excess CPM
Above background
Corrected CPM
Background sourceNo data
Background protectionLearning normally

Radiation graphs

Main count-rate graph first, followed by supporting diagnostics in a compact two-column grid.

Count rate, background and thresholds

Unit: CPM — counts per minute. CPM is the detector pulse rate normalised to one minute. This graph shows raw CPM, the 5-minute rolling rate, dead-time-corrected CPM, the resolved background reference, dynamic +1σ/+2σ/+3σ background bands, and the configured warning and alarm thresholds.

Vertical dotted markers: detected radiation-event peaks. Yellow marks an event around 2–3σ above background, orange marks 3–5σ, and pink/red marks 5σ or higher. These are event markers, not extra threshold lines.

Counts per second

Unit: CPS — counts per second. The number of accepted detector pulses in each second. This gives the fastest view of changing radiation activity and can reveal brief spikes.

Counts per upload

Unit: counts (detector pulses). The non-overlapping number of detector pulses accumulated during each upload/reporting interval. This is an interval total rather than a rate.

Cumulative detector counts

Unit: counts (detector pulses). The long-running detector pulse total. It normally rises continuously; device restarts or counter resets can appear as resets or discontinuities.

Significance above background

Unit: σ (sigma) — standard deviations, dimensionless. This shows how far the measured count rate is from the learned background in statistical terms. The 2σ and 3σ lines provide reference levels for increasingly unusual departures from normal background.

CPM distribution histogram

X-axis: CPM; Y-axis: number of samples. The histogram groups recorded CPM readings into ranges and shows how often each range occurred. A tight distribution usually indicates a stable background; widening or extra peaks can help identify changing conditions or noise.

Dose-rate trend

Unit: µSv/h — microsieverts per hour. This is the estimated or calibrated ionising-radiation dose rate derived from detector counts. Its accuracy depends on the detector, energy response, geometry and the CPM-to-dose calibration used.

Environment and cabinet

Live environmental history from the same freshest sensor stream used by Live Data. Temperature, humidity and pressure are merged even when firmware sends them separately from Geiger measurements.

Temperature18.1 °C2 h old
Humidity55.3 %2 h old
Pressure1,018.6 hPa2 h old

Radiation events

HydroTrack marks statistically elevated periods so the start, peak and end of an event are easy to identify.

Events in range0
Strongest eventNone
Event threshold2.00 σ
No ≥2σ radiation events were detected in the selected range.

Instrument, environment and data quality

Latest detector condition and measurement configuration. Sensitive network and hardware identifiers are intentionally not exposed on the public page.

Detector healthGOOD
Detector noiseLOW
Critical threshold1,000 CPM
Calibration statusDose estimate
Wi-Fi signal-88 dBm
Supply voltageNot reported
Cabinet / tamperOPEN / TAMPER
Tube high voltageNot fitted
HV statusNOT_FITTED
Average pulse width212.9 µs
Invalid pulse widths6.03 %
Dead-time loss0.028 %
Rejected pulses42,332
Pulse signalVALID_PULSES
Measurement assurancePARTIAL_NO_HV_MONITOR
Station self-testPASS
Input powerNot fitted
Power statusNOT_FITTED
Audit continuity#341
Samples displayed0
Instrument record and calibration details
Station IDCD76B144
Monitor typeGeiger radiation monitor
FirmwareHRV9.5.29-TECHNICIAN-LOGIN-FIX
Detector serialNot configured
Configured efficiency100.0 %
Configured CPM range0 – 100,000 CPM
Calibration dateNot configured
Calibration dueNot configured
Calibration laboratoryNot configured
Uptime4d 2h
Upload counters936 success / 2,308 failed
Background sourceNo data
HV supervisionNot fitted / disabled
Expected tube HV350 – 550 V
Last pulse width212.0 µs
Dead-time rejected9,629
Measurement validityVALID
Station assurance82/100 · DEGRADED
Self-test summaryAll configured station checks passed
Audit chain hashA7D24C7E